Syncing a Quantum Transmitter (Belly Box) to the Action Trackporter®
- Start with both Trackporter® and transmitter powered “OFF”.
- Press and hold the ENABLE button and the WINCH CONTROL JOYSTICK in the UP position, at the same time release the E-STOP. Hold for 10 seconds.
- Release the ENABLE and WINCH CONTROL JOYSTICK when the ENABLE and TRANSMITTER POWER INDICATORS start blinking.
- Rotate main power switch to the ON position. Only the ENABLE INDICATOR (Green) should start to blink on the Transmitter.
- Press and hold the ENABLE button until the ENABLE INDICATOR LED turns solid green and synching is complete.